<< Chapter < Page Chapter >> Page >

Pinch off voltage, v P

The voltage needed to turn “OFF” a JFET. When designing circuits it is essential that the pinch-off voltage be determined to avoid current leakage which can dramatically reduce performance.

Threshold voltage, v T

The voltage needed to turn “ON” a MOSFET. This is a critical parameter in effective circuit design.

Channel resistance, r DS

The resistance between the drain and source in the channel. This influences the amount of current being transferred between the two terminals.

Power dissipation, p D

The power dissipation determines the amount of heat generated by the transistor. This becomes a real problem since the transport properties deteriorate as the channel is heated.

Effective charge carrier mobility, µ n

The charge carrier mobility determines how quickly the charge carrier can move through the channel. In most cases higher mobility leads to better device performance. The mobility can also be used to gauge the impurity, defect, temperature, and charge carrier concentrations

Transconductance gain, g m (transfer admittance)

The g m is a measure of gain or amplification of a current for a given change in gate voltage. This is critical for amplification type electronics.

Equipment needs

  1. PC with Keithley Interactive Test Environment (KITE) software.
  2. Semiconductor characterization system (Keithley 4200-SCS or equivalent).
  3. Probe station.
  4. Probe tips.
  5. Protective gloves.

Measurement of (v-i) characteristics

The Semiconductor Characterization System is an automated system that provides both (V-I) and (V-C) characterization of semiconductor devices and test structures. The advanced digital sweep parameter analyzer provides sub-micron characterization with accuracy and speed. This system utilizes the Keithley Interactive Test Environment (KITE) software designed specifically for semiconductor characterization.

Procedure

  • Step 1 - Connect the probe tips to the probe station. Then attach the banana plugs from the probe station to the BNC connector, making sure not to connect to ground.
  • Step 2 – Select the appropriate connections for your test from [link] .
  • Step 3 – Place your transistor sample on the probe station, but don’t let the probe tips touch the sample to prevent possible electric shock(during power up, the SMU may momentarily output high voltage).
  • Step 4 – Turn on power located on the lower right of the front panel. The power up sequence may take up to 2 minutes.
  • Step 5 – Start KITE software. [link] shows the interface window.
  • Step 6 – Select the appropriate setup from the Project Tree drop down (top left).
  • Step 7 – Match the Definition tab terminal connections to the physical connections of probe tips. If connection is not yet matched you can assign/reassign the terminal connections by using the arrow key next to the instrument selection box that displays a list of possible connections. Select the connection in the instrument selection box that matches the physical connection of the device terminal.
  • Step 8 – Set the Force Measure settings for each terminal. Fill in the necessary function parameters such as start, stop, step size, range, and compliance. For typical voltage sweeps you’ll want to force the voltage between the drain and source while measuring the current at the drain. Make sure to conduct several voltage sweeps at various forced gate voltages to aid in the analysis.
  • Step 9 – Check the current box/voltage box if you desire the current/voltage to be recorded in the Sheet tab Data worksheet and be available for plotting in the Graph tab.
  • Step 10 – Now make contact to your sample with the probe tips
  • Step 11 – Run the measurement setup by clicking the green Run arrow on the tool bar located above the Definition tab. Make sure the measuring indicator light at bottom right hand corner of the front panel is lit.
  • Step 12 – Save data by clicking on the Sheet tab then selecting the Save As tab. Select the file format and location.

Questions & Answers

what is biology
Hajah Reply
the study of living organisms and their interactions with one another and their environments
AI-Robot
what is biology
Victoria Reply
HOW CAN MAN ORGAN FUNCTION
Alfred Reply
the diagram of the digestive system
Assiatu Reply
allimentary cannel
Ogenrwot
How does twins formed
William Reply
They formed in two ways first when one sperm and one egg are splited by mitosis or two sperm and two eggs join together
Oluwatobi
what is genetics
Josephine Reply
Genetics is the study of heredity
Misack
how does twins formed?
Misack
What is manual
Hassan Reply
discuss biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles
Joseph Reply
what is biology
Yousuf Reply
the study of living organisms and their interactions with one another and their environment.
Wine
discuss the biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles in an essay form
Joseph Reply
what is the blood cells
Shaker Reply
list any five characteristics of the blood cells
Shaker
lack electricity and its more savely than electronic microscope because its naturally by using of light
Abdullahi Reply
advantage of electronic microscope is easily and clearly while disadvantage is dangerous because its electronic. advantage of light microscope is savely and naturally by sun while disadvantage is not easily,means its not sharp and not clear
Abdullahi
cell theory state that every organisms composed of one or more cell,cell is the basic unit of life
Abdullahi
is like gone fail us
DENG
cells is the basic structure and functions of all living things
Ramadan
What is classification
ISCONT Reply
is organisms that are similar into groups called tara
Yamosa
in what situation (s) would be the use of a scanning electron microscope be ideal and why?
Kenna Reply
A scanning electron microscope (SEM) is ideal for situations requiring high-resolution imaging of surfaces. It is commonly used in materials science, biology, and geology to examine the topography and composition of samples at a nanoscale level. SEM is particularly useful for studying fine details,
Hilary
cell is the building block of life.
Condoleezza Reply
Got questions? Join the online conversation and get instant answers!
Jobilize.com Reply

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Physical methods in chemistry and nano science. OpenStax CNX. May 05, 2015 Download for free at http://legacy.cnx.org/content/col10699/1.21
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Physical methods in chemistry and nano science' conversation and receive update notifications?

Ask