<< Chapter < Page Chapter >> Page >
(1.00 J) / ( 50.0 kg ) = 0.0200 J/kg = 2.00 rad.

If the same 1.00 J of ionizing energy were absorbed in her 2.00-kg forearm alone, then the dose to the forearm would be

(1.00 J) / ( 2.00 kg ) = 0.500 J/kg = 50.0 rad,

and the unaffected tissue would have a zero rad dose. While calculating radiation doses, you divide the energy absorbed by the mass of affected tissue. You must specify the affected region, such as the whole body or forearm in addition to giving the numerical dose in rads. The SI unit for radiation dose is the gray (Gy)    , which is defined to be

1 Gy = 1 J/kg = 100 rad.

However, the rad is still commonly used. Although the energy per kilogram in 1 rad is small, it has significant effects since the energy causes ionization. The energy needed for a single ionization is a few eV, or less than 10 18 J size 12{"10" rSup { size 8{ - "18"} } `J} {} . Thus, 0.01 J of ionizing energy can create a huge number of ion pairs and have an effect at the cellular level.

The effects of ionizing radiation may be directly proportional to the dose in rads, but they also depend on the type of radiation and the type of tissue. That is, for a given dose in rads, the effects depend on whether the radiation is α, β, γ, size 12{α,`β`,γ,} {} x-ray, or some other type of ionizing radiation. In the earlier discussion of the range of ionizing radiation, it was noted that energy is deposited in a series of ionizations and not in a single interaction. Each ion pair or ionization requires a certain amount of energy, so that the number of ion pairs is directly proportional to the amount of the deposited ionizing energy. But, if the range of the radiation is small, as it is for α size 12{α} {} s, then the ionization and the damage created is more concentrated and harder for the organism to repair, as seen in [link] . Concentrated damage is more difficult for biological organisms to repair than damage that is spread out, so short-range particles have greater biological effects. The relative biological effectiveness (RBE) or quality factor     (QF) is given in [link] for several types of ionizing radiation—the effect of the radiation is directly proportional to the RBE. A dose unit more closely related to effects in biological tissue is called the roentgen equivalent man or rem and is defined to be the dose in rads multiplied by the relative biological effectiveness.

rem = rad × RBE
The image shows ionization created in cells by gamma and alpha radiation. Series of cells are shown through which a gamma ray passes causing ionization whose density is low. Another series of cells are shown through which an alpha ray passes causing ionization whose density is high.
The image shows ionization created in cells by α and γ size 12{γ} {} radiation. Because of its shorter range, the ionization and damage created by α size 12{α} {} is more concentrated and harder for the organism to repair. Thus, the RBE for α size 12{α} {} s is greater than the RBE for γ size 12{γ} {} s, even though they create the same amount of ionization at the same energy.

So, if a person had a whole-body dose of 2.00 rad of γ size 12{γ} {} radiation, the dose in rem would be (2.00 rad)(1) = 2.00 rem whole body . If the person had a whole-body dose of 2.00 rad of α size 12{α} {} radiation, then the dose in rem would be (2.00 rad)(20) = 40.0 rem whole body . The α size 12{α} {} s would have 20 times the effect on the person than the γ size 12{γ} {} s for the same deposited energy. The SI equivalent of the rem is the sievert    (Sv), defined to be Sv = Gy × RBE size 12{"Sv"="Gy" times "RBE"} {} , so that

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, College physics. OpenStax CNX. Jul 27, 2015 Download for free at http://legacy.cnx.org/content/col11406/1.9
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'College physics' conversation and receive update notifications?

Ask