<< Chapter < Page Chapter >> Page >

Procedural error

A faulty measuring process may include inappropriate physical environment, procedural mistakes and lack of understanding of the process of measurement. For example, if we are studying magnetic effect of current, then it would be erroneous to conduct the experiment in a place where strong currents are flowing nearby. Similarly, while taking temperature of human body, it is important to know which of the human parts is more representative of body temperature.

This error type can be minimized by periodic assessment of measurement process and improvising the system in consultation with subject expert or simply conducting an audit of the measuring process in the light of new facts and advancements.

Personal bias

A personal bias is introduced by human habits, which are not conducive for accurate measurement. Consider for example, the reading habit of a person. He or she may have the habit of reading scales from an inappropriate distance and from an oblique direction. The measurement, therefore, includes error on account of parallax.

Parallax

The position of pencil changes with respect to a mark on the background.

We can appreciate the importance of parallax by just holding a finger (pencil) in the hand, which is stretched horizontally. We keep the finger in front of our eyes against some reference marking in the back ground. Now, we look at the finger by closing one eye at a time and note the relative displacement of the finger with respect to the mark in the static background. We can do this experiment any time as shown in the figure above. The parallax results due to the angle at which we look at the object.

It is important that we read position of a pointer or a needle on a scale normally to avoid error on account of parallax.

Parallax

Parallax error is introduced as we may read values at an angle.

Random errors

Random error unlike systematic error is not unidirectional. Some of the measured values are greater than true value; some are less than true value. The errors introduced are sometimes positive and sometimes negative with respect to true value. It is possible to minimize this type of error by repeating measurements and applying statistical technique to get closer value to the true value.

Another distinguishing aspect of random error is that it is not biased. It is there because of the limitation of the instrument in hand and the limitation on the part of human ability. No human being can repeat an action in exactly the same manner. Hence, it is likely that same person reports different values with the same instrument, which measures the quantity correctly.

Least count error

Least count error results due to the inadequacy of resolution of the instrument. We can understand this in the context of least count of a measuring device. The least count of a device is equal to the smallest division on the scale. Consider the meter scale that we use. What is its least count? Its smallest division is in millimeter (mm). Hence, its least count is 1 mm i.e. 10 - 3 m i.e. 0.001 m. Clearly, this meter scale can be used to measure length from 10 - 3 m to 1 m. It is worth to know that least count of a vernier scale is 10 - 4 m and that of screw gauge and spherometer 10 - 5 m.

Returning to the meter scale, we have the dilemma of limiting ourselves to the exact measurement up to the precision of marking or should be limited to a step before. For example, let us read the measurement of a piece of a given rod. One end of the rod exactly matches with the zero of scale. Other end lies at the smallest markings at 0.477 m (= 47.7 cm = 477 mm). We may argue that measurement should be limited to the marking which can be definitely relied. If so, then we would report the length as 0.47 m, because we may not be definite about millimeter reading.

This is, however, unacceptable as we are sure that length consists of some additional length – only thing that we may err as the reading might be 0.476 m or 0.478 m instead of 0.477 m. There is a definite chance of error due to limitation in reading such small divisions. We would, however, be more precise and accurate by reporting measurement as 0.477 ± some agreed level of anticipated error. Generally, the accepted level of error in reading the smallest division is considered half the least count. Hence, the reading would be :

x = 0.477 ± 0.001 2 m

x = 0.477 ± 0.0005 m

If we report the measurement in centimeter,

x = 47.7 ± 0.05 c m

If we report the measurement in millimeter,

x = 477 ± 0. 5 m m

Mean value of measurements

It has been pointed out that random error, including that of least count error, can be minimized by repeating measurements. It is so because errors are not unidirectional. If we take average of the measurements from the repeated measurements, it is likely that we minimize error by canceling out errors in opposite directions.

Here, we are implicitly assuming that measurement is free of “systematic errors”. The averaging of the repeated measurements, therefore, gives the best estimate of “true” value. As such, average or mean value ( a m ) of the measurements (excluding "off beat" measurements) is the notional “true” value of the quantity being measured. As a matter of fact, it is reported as true value, being our best estimate.

a m = a 1 + a 2 + . . + a n n

a m = Σ 0 n a i n

Questions & Answers

prostaglandin and fever
Maha Reply
Discuss the differences between taste and flavor, including how other sensory inputs contribute to our  perception of flavor.
John Reply
taste refers to your understanding of the flavor . while flavor one The other hand is refers to sort of just a blend things.
Faith
While taste primarily relies on our taste buds, flavor involves a complex interplay between taste and aroma
Kamara
which drugs can we use for ulcers
Ummi Reply
omeprazole
Kamara
what
Renee
what is this
Renee
is a drug
Kamara
of anti-ulcer
Kamara
Omeprazole Cimetidine / Tagament For the complicated once ulcer - kit
Patrick
what is the function of lymphatic system
Nency Reply
Not really sure
Eli
to drain extracellular fluid all over the body.
asegid
The lymphatic system plays several crucial roles in the human body, functioning as a key component of the immune system and contributing to the maintenance of fluid balance. Its main functions include: 1. Immune Response: The lymphatic system produces and transports lymphocytes, which are a type of
asegid
to transport fluids fats proteins and lymphocytes to the blood stream as lymph
Adama
what is anatomy
Oyindarmola Reply
Anatomy is the identification and description of the structures of living things
Kamara
what's the difference between anatomy and physiology
Oyerinde Reply
Anatomy is the study of the structure of the body, while physiology is the study of the function of the body. Anatomy looks at the body's organs and systems, while physiology looks at how those organs and systems work together to keep the body functioning.
AI-Robot
what is enzymes all about?
Mohammed Reply
Enzymes are proteins that help speed up chemical reactions in our bodies. Enzymes are essential for digestion, liver function and much more. Too much or too little of a certain enzyme can cause health problems
Kamara
yes
Prince
how does the stomach protect itself from the damaging effects of HCl
Wulku Reply
little girl okay how does the stomach protect itself from the damaging effect of HCL
Wulku
it is because of the enzyme that the stomach produce that help the stomach from the damaging effect of HCL
Kamara
function of digestive system
Ali Reply
function of digestive
Ali
the diagram of the lungs
Adaeze Reply
what is the normal body temperature
Diya Reply
37 degrees selcius
Xolo
37°c
Stephanie
please why 37 degree selcius normal temperature
Mark
36.5
Simon
37°c
Iyogho
the normal temperature is 37°c or 98.6 °Fahrenheit is important for maintaining the homeostasis in the body the body regular this temperature through the process called thermoregulation which involves brain skin muscle and other organ working together to maintain stable internal temperature
Stephanie
37A c
Wulku
what is anaemia
Diya Reply
anaemia is the decrease in RBC count hemoglobin count and PVC count
Eniola
what is the pH of the vagina
Diya Reply
how does Lysin attack pathogens
Diya
acid
Mary
I information on anatomy position and digestive system and there enzyme
Elisha Reply
anatomy of the female external genitalia
Muhammad Reply
Got questions? Join the online conversation and get instant answers!
Jobilize.com Reply

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Physics for k-12. OpenStax CNX. Sep 07, 2009 Download for free at http://cnx.org/content/col10322/1.175
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Physics for k-12' conversation and receive update notifications?

Ask