<< Chapter < Page Chapter >> Page >
The current-voltage sweep is one of the fundamental experiments used to characterize the behavior of a diode. The Diode IV Sweep lab is designed as a laboratory or at-home experiment. Low cost National Instruments Data Acquisition products are used to excite and acquire data from the Diode-Resistor network.

Diode iv sweep using national instruments low cost data acquisition

Introduction

The diode is a basic circuit element that possesses nonlinear IV characteristics. In contrast to a simpleresistor, doubling diode current does not necessarily double the voltage across the diode. In order to visualize this nonlinearrelationship, it is common to plot diode current vs. voltage on a 2D graph. This graph can also be used at a later point to perform“load line” calculations on circuits with diodes.

In this exercise, the experimenter will construct a simple circuit to measure the IV characteristic of adiode. The Low Cost USB DAQ will be used as a programmable voltage source as well as an analog measurement device. The experimentaldata collected can be compared to expected theoretical data to draw conclusions regarding measurement noise, model shortcomings, anddata acquisition.

Pre-lab assignment

  • Research the exponential diode model using textbooks, the internet, or any other source. This model is more commonly referredto as the “ideal diode model”. What other diode models can you find?
  • What formula(s) can you find relating diode current and voltage? Note that the exponential, or “ideal diode model” shouldhave an exponential term.
  • Search Google for “Phillips 1N914” and open up the pdf datasheet. Find the graph of diode forward current vs voltage andnote your observations. Does the forward IV curve look exponential? How does the reverse IV curve look?
  • Use a simulation package such as Multisim to obtain the IV characteristic of a simulated diode. Do this by sweeping either the diode current or voltage, andmeasuring the other quantity.
  • Become familiar with the National Instruments USB 6008 and 6009 data acquisition devices. These datasheets are available on www.ni.com .

Theory

One commonly used method of modeling a diode is the “ideal diode model”. Using this model, diode voltage andcurrent are related according to the following formula:

Ideal Diode Model

Since Is is typically very small (1E-12), this equation is commonly simplified to:

Simplfied Diode Model Equation

Note that in the formula, Is stands for the saturation current which is around 1E-12 A, and Vt is a temperaturedependent constant equal to 0.0259 V at 300 degrees K. Id and Vd represent diode current and voltage respectively.

Therefore, a theoretical diode IV curve can be plotted using LabVIEW:

IV Curve plotted using LabVIEW

Hardware and software required

  • 10 Ohm resistor
  • Diode
  • National Instruments Low Cost USB DAQ
  • LabVIEW 8.20 software (LabVIEW 7.1 or 8.0 will work as well)

Labratory procedure

1) Construct the following circuit and connect to the USB 6008/6009. By outputting a certain voltage at AO 0 and measuring thevoltage at AI 3+, the experimenter can obtain a data point containing diode voltage and current. The diode voltage is simplythe voltage at node AI 3+, and the diode current is identical to the resistor current (Ohm’s Law).

Circuit for Measuring Diode IV Curve

2) Use a DMM to measure the actual resistance used for R1 in the circuit above (take R1 out of the circuit for measurement). This will help to obtain a moreaccurate current reading.

3) Using the DAQ Assistant Express VI, construct the following LabVIEW block diagram. Note that the userwill be able to select the number of IV data points to collect, as well as the ending sweep voltage for AO 0. Select this voltage lowenough to ensure that resistor R1 does not exceed its power specification.

LabVIEW Block Diagram Used to Measure Diode IV Curve

4) Run the VI several times using different values for the number of data points and sweep ending voltage.Record your observations and print out three diode IV curves with different numbers of data points.

Post-lab questions

  • Did the measured diode characteristic curve closely resemble what you expected? How closely did this curve match the datasheet,simulation, and theoretical data you researched earlier?
  • The measured IV curve may have contained some noise. Elaborate on some possible sources of this noise (think about yoursurroundings). Can you think of a way to eliminate some of the undesired noise from the signal? Would you do this in hardware orsoftware?
  • What real-world situations would require a designer to measure the diode characteristic curve?
  • What quantities could you measure for a bipolar junction transistor (BJT) using the low cost USB acquisition device? Explain how you would make your measurements.

Questions & Answers

what is biology
Hajah Reply
the study of living organisms and their interactions with one another and their environments
AI-Robot
what is biology
Victoria Reply
HOW CAN MAN ORGAN FUNCTION
Alfred Reply
the diagram of the digestive system
Assiatu Reply
allimentary cannel
Ogenrwot
How does twins formed
William Reply
They formed in two ways first when one sperm and one egg are splited by mitosis or two sperm and two eggs join together
Oluwatobi
what is genetics
Josephine Reply
Genetics is the study of heredity
Misack
how does twins formed?
Misack
What is manual
Hassan Reply
discuss biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles
Joseph Reply
what is biology
Yousuf Reply
the study of living organisms and their interactions with one another and their environment.
Wine
discuss the biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles in an essay form
Joseph Reply
what is the blood cells
Shaker Reply
list any five characteristics of the blood cells
Shaker
lack electricity and its more savely than electronic microscope because its naturally by using of light
Abdullahi Reply
advantage of electronic microscope is easily and clearly while disadvantage is dangerous because its electronic. advantage of light microscope is savely and naturally by sun while disadvantage is not easily,means its not sharp and not clear
Abdullahi
cell theory state that every organisms composed of one or more cell,cell is the basic unit of life
Abdullahi
is like gone fail us
DENG
cells is the basic structure and functions of all living things
Ramadan
What is classification
ISCONT Reply
is organisms that are similar into groups called tara
Yamosa
in what situation (s) would be the use of a scanning electron microscope be ideal and why?
Kenna Reply
A scanning electron microscope (SEM) is ideal for situations requiring high-resolution imaging of surfaces. It is commonly used in materials science, biology, and geology to examine the topography and composition of samples at a nanoscale level. SEM is particularly useful for studying fine details,
Hilary
cell is the building block of life.
Condoleezza Reply
Got questions? Join the online conversation and get instant answers!
Jobilize.com Reply

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Electronics experiments using usb data acquisition. OpenStax CNX. Dec 15, 2006 Download for free at http://cnx.org/content/col10393/1.1
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Electronics experiments using usb data acquisition' conversation and receive update notifications?

Ask