<< Chapter < Page Chapter >> Page >
Using the eZ430-RF2500 Development Tool use ADC10 to perform a single temperature sample on channel A10 (on-chip temperature sensor) each minute during 1 hour.

Laboratory signal acquisition: lab1 - sar adc10 conversion

Introduction

This laboratory gives examples of the uses of the ADC types available in the hardware development kits. A different laboratory is developed for each kit, taking into account that both the ADC10 and the SD16_A laboratories implement a temperature data logger. The ADC12 laboratory also uses operational amplifiers to perform the analogue signal conditioning.

Overview

This laboratory ( Lab1_ADC.c ) implements a temperature data logger using the hardware kit’s integrated temperature sensor. The device is configured to perform an acquisition each minute for one hour. Each temperature’s (ºC) value is transferred to flash info memory segment B and C. When the microcontroller is not performing any task, it enters into low power mode.

Resources

The ADC10 module uses V REF+ = 1.5 V as the reference voltage.

It is necessary to configure the ADC10 to use the integrated temperature sensor (A10) as an input. Timer_A generates an interrupt once every second that starts conversion in the ADC10. At the end of a conversion, an interrupt is requested by the converter and the temperature value is written to flash memory.

The voltage value is converted into temperature following the equation provided in ADC10 section of the MSP430 User’s Guide<slau144e.pdf>. After transferring the value to the flash memory, the system returns to low power mode LPM3.

The resources used by the application are:

- ADC10;

- Timer_A;

- Ports I/O;

- Interrupts;

- Low power mode.

Software application organization

The application starts by stopping the Watchdog Timer.

The system checks for calibration constants on info memory segment A. The CPU execution will be trapped if it does not find this information.

Digitally controller oscillator (DCO) is set to 1 MHz, providing clock source for MCLK and SMCLK, while the Basic Clock System+ is configured to set ACLK to 1.5 kHz.

Controller’s flash timing is obtained from MCLK divided by three to comply with the device specifications.

Port P1.0 is configured as an output and will blink the once LED every second.

The ADC10 is configured to use the input channel corresponding to the on-chip temperature sensor (channel A10). The configuration includes the activation of the internal reference voltage V REF+ = 1.5 V and the selection of ADC10OSC as clock signal. The converter is configured to perform a single-channel single-conversion. At the end of conversion, an interrupt is requested.

The Timer_A is configured to generate an interrupt once every second. ACLK/8 is selected as the clock signal using the VLOCLK as clock source and will count until the TACCR0 value is reached (in up mode). The system then enters into low power mode and waits for an interrupt.

Flash memory pointers and interrupt counters are initialized. The Timer_A ISR increments the variable counter and when this variable reaches the value 60 (1 minute), the software start of conversion is requested. At the end of this ISR, the system returns to low power mode.

Questions & Answers

what is phylogeny
Odigie Reply
evolutionary history and relationship of an organism or group of organisms
AI-Robot
ok
Deng
what is biology
Hajah Reply
the study of living organisms and their interactions with one another and their environments
AI-Robot
what is biology
Victoria Reply
HOW CAN MAN ORGAN FUNCTION
Alfred Reply
the diagram of the digestive system
Assiatu Reply
allimentary cannel
Ogenrwot
How does twins formed
William Reply
They formed in two ways first when one sperm and one egg are splited by mitosis or two sperm and two eggs join together
Oluwatobi
what is genetics
Josephine Reply
Genetics is the study of heredity
Misack
how does twins formed?
Misack
What is manual
Hassan Reply
discuss biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles
Joseph Reply
what is biology
Yousuf Reply
the study of living organisms and their interactions with one another and their environment.
Wine
discuss the biological phenomenon and provide pieces of evidence to show that it was responsible for the formation of eukaryotic organelles in an essay form
Joseph Reply
what is the blood cells
Shaker Reply
list any five characteristics of the blood cells
Shaker
lack electricity and its more savely than electronic microscope because its naturally by using of light
Abdullahi Reply
advantage of electronic microscope is easily and clearly while disadvantage is dangerous because its electronic. advantage of light microscope is savely and naturally by sun while disadvantage is not easily,means its not sharp and not clear
Abdullahi
cell theory state that every organisms composed of one or more cell,cell is the basic unit of life
Abdullahi
is like gone fail us
DENG
cells is the basic structure and functions of all living things
Ramadan
What is classification
ISCONT Reply
is organisms that are similar into groups called tara
Yamosa
in what situation (s) would be the use of a scanning electron microscope be ideal and why?
Kenna Reply
A scanning electron microscope (SEM) is ideal for situations requiring high-resolution imaging of surfaces. It is commonly used in materials science, biology, and geology to examine the topography and composition of samples at a nanoscale level. SEM is particularly useful for studying fine details,
Hilary
Got questions? Join the online conversation and get instant answers!
Jobilize.com Reply

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Teaching and classroom laboratories based on the “ez430” and "experimenter's board" msp430 microcontroller platforms and code composer essentials. OpenStax CNX. May 19, 2009 Download for free at http://cnx.org/content/col10706/1.3
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Teaching and classroom laboratories based on the “ez430” and "experimenter's board" msp430 microcontroller platforms and code composer essentials' conversation and receive update notifications?

Ask